Features
Configuration Code
Applications
DescriptionFeaturesSpecificaitonsConfiguration CodeApplications● Service and maintenance ● Replacement of defective devices ● Support of commissioning process and installation ● Performance and efficiency measurement - Evaluation and assessments - Capacity measurement of pumps - Monitoring of regulating valves● Water and waste water industry - hot water, cooling water, potable water, sea water etc.) ● Petrochemical industry ● Chemical industry -chlorine, alcohol, acids, .thermal oils.etc ● Refrigeration and air conditioning systems ● Food , beverage and pharmaceutical industry ● Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc ● Metallurgy and mining applications ● Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.Specificaitons
Transmitter:Measurement principle | Ultrasonic transit-time difference correlation principle |
Flow velocity range | 0.01 to 12 m/s, bi-directional |
Resolution | 0.25mm/s |
Repeatability | 0.2% of reading |
Accuracy | ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s |
Response time | 0.5s |
Sensitivity | 0.003m/s |
Damping of displayed value | 0-99s(selectable by user) |
Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
Power Supply | AC: 85-265V DC: 24V/500mA |
Enclosure type | Wall-mounted |
Degree of protection | IP66 according to EN60529 |
Operating temperature | -20℃ to +60℃ |
Housing material | Fiberglass |
Display | 4 line×16 English letters LCD graphic display, backlit |
Units | User Configured (English and Metric) |
Rate | Rate and Velocity Display |
Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
Thermal energy | unit GJ,KWh can be optional |
Communication | 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger |
Security | Keypad lockout, system lockout |
Size | 244*196*114mm |
Weight | 2.4kg |
Degree of protection | IP65 according to EN60529.(IP67 or IP68 Upon request) |
Suited Liquid Temperature | Std. Temp.: -35℃~85℃ for short periods up to 120℃ |
High Temp.: -35℃~200℃ for short periods up to 250℃ | |
Pipe diameter range | 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L |
Transducer Size | Type S 48(h)*28(w)*28(d)mm |
Type M 60(h)*34(w)*32(d)mm | |
Type L 80(h)*40(w)*42(d)mm | |
Material of transducer | Aluminum (standard temperature), and peek (high temperature) |
Cable Length | Std:10m |
Temperature Sensor | Pt1000 Clamp-on Accuracy: ±0.1% |